Test gauge, ±0.25% FSD

A test gauge is a high-resolution reference gauge used to check working gauges and to witness hydrostatic tests. Pioneer's test gauge reads to ±0.25% FSD as per IS 3624, has an SS 316 Bourdon tube and socket in an SS 304 case, and comes with 100, 150, 200 or 250 mm dials and a knife-edge pointer for fine reading.

Accuracy
±0.25% FSD, IS 3624
Dial
100 to 250 mm
Pointer
Knife-edge

Quotation within one working day of your BOQ. Supply across India and export, FOB Nhava Sheva.

Pioneer test pressure gauge with large finely graduated dial

How it works and when to use it

On a hydro test the inspector signs against the number on the gauge, so the gauge has to be four times better than the ones in the plant. The large dial and fine graduations let the reading be taken to a fraction of a division, and the knife-edge pointer cuts parallax.

Pick a range so the test pressure falls in the upper middle of the scale, and ask for a calibration certificate from an NABL-accredited laboratory when your quality plan or the third-party inspector needs one.

Versions

  • 150 mm and 200 mm. Most common for hydro tests and site witness testing.
  • 250 mm. For calibration benches and laboratories where finest resolution matters.
  • Dual scale. kg/cm² with psi or bar for export inspection.

Typical applications

  • Hydrostatic tests of pipelines, vessels and fire mains
  • Calibration of working pressure gauges
  • Quality labs and test benches
  • Third-party inspection and site commissioning

Specification

Standard specification
ParameterValue
Accuracy±0.25% FSD as per IS 3624
Dial size100, 150, 200, 250 mm
Ranges0–1, 1.6, 2.5, 4, 6, 10, 16, 25, 40, 60, 100, 160, 250, 400, 600 kg/cm²
Unitskg/cm², psi, bar; single or dual scale
Over-range130% of full scale
Measuring elementSS 316 Bourdon tube with SS 316 socket
MovementSS 304
CaseSS 304, weatherproof and dust-proof
ProtectionIP 65 / IP 67
WindowShatterproof or toughened glass
PointerKnife-edge, micrometer adjustable
Process connection3/8" or 1/2" BSP / NPT, M20 × 1.5
MountingDirect, bottom entry
FillingDry or glycerine filled

Other ranges, units, connections and dial sizes on request. Send your medium, range and connection and we match the model.

Consultant specification clause

Paste into your technical specification or BOQ and adjust ranges and quantities.

  1. Test gauges shall be Bourdon tube type, SS 316 tube and socket, SS 304 case and movement.
  2. Accuracy ±0.25% FSD as per IS 3624; dial 150 mm minimum with knife-edge micrometer pointer.
  3. Range so that the test pressure lies between 50% and 75% of full scale.
  4. Supplied with a calibration certificate from an NABL-accredited laboratory. Make: Pioneer Industrial Instruments, Pune, or approved equivalent.

Questions buyers ask

What accuracy should a test gauge have?

At least four times better than the gauge or system being tested. Pioneer's test gauge is ±0.25% FSD, so it can check ±1% FSD working gauges.

Can you supply an NABL calibration certificate?

Yes, on request, from an NABL-accredited laboratory. Mention it in your enquiry so it is included in the quotation and delivery time.

Which range for a hydro test at 15 kg/cm²?

0–25 kg/cm² puts 15 kg/cm² at 60% of full scale. Try the range selector for other pressures.

What is the difference between a test gauge and a normal pressure gauge?

A test gauge is about four times more accurate (±0.25% FSD against ±1% FSD), has a larger, finely divided dial and a knife-edge pointer, and is used as a reference rather than for permanent plant indication.

Related